根據(jù)區(qū)域環(huán)境確定發(fā)熱電纜安裝時(shí)的布線間距
來(lái)源:安邦電地暖 dwrouniu.com 瀏覽次數(shù):4737 日期:2012年12月15日
由于地域環(huán)境溫度差異,根據(jù)部分區(qū)域安裝電地暖發(fā)熱電纜的布線間距,及所需覆蓋面積的熱量制作以下參考表:
北方城市
|
耗熱量
(W·m-2)
|
|
80
|
100
|
120
|
150
|
200
|
250
|
300
|
鄭州
|
20.0
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
濟(jì)南
|
20.2
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
青島
|
20.2
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
煙臺(tái)
|
20.2
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
石家莊
|
20.3
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
天津
|
20.5
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
北京
|
20.6
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
大連
|
20.6
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
太原
|
20.8
|
0.4~0.9
|
0.5~1.0
|
0.6~1.0
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
沈陽(yáng)
|
21.2
|
0.5~0.9
|
0.6~1.0
|
0.7~1.0
|
0.9~1.0
|
1.0
|
1.0
|
1.0
|
呼和浩特
|
21.3
|
0.5~0.9
|
0.6~1.0
|
0.7~1.0
|
0.9~1.0
|
1.0
|
1.0
|
1.0
|
長(zhǎng)春
|
21.7
|
0.5~0.9
|
0.7~1.0
|
0.8~1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
哈爾濱
|
21.9
|
0.6~0.9
|
0.7~1.0
|
0.9~1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
齊齊哈爾
|
21.9
|
0.6~0.9
|
0.7~1.0
|
0.9~1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
北方城市
|
耗熱量
(W·m-2)
|
線型荷載為q0=17W/m發(fā)熱電纜布線間距d下得 敷設(shè)面積比率
|
80
|
100
|
120
|
150
|
200
|
250
|
300
|
鄭州
|
20.0
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
濟(jì)南
|
20.2
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
青島
|
20.2
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
煙臺(tái)
|
20.2
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
石家莊
|
20.3
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
天津
|
20.5
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
北京
|
20.6
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
大連
|
20.6
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
太原
|
20.8
|
0.2~0.5
|
0.3~0.7
|
0.3~0.8
|
0.4~1.0
|
0.6~1.0
|
0.7~0.9
|
0.9~1.0
|
沈陽(yáng)
|
21.2
|
0.3~0.5
|
0.4~0.6
|
0.4~0.7
|
0.5~1.0
|
0.6~1.0
|
0.8~1.0
|
0.8~1.0
|
呼和浩特
|
21.3
|
0.3~0.5
|
0.4~0.6
|
0.4~0.7
|
0.5~1.0
|
0.6~1.0
|
0.8~1.0
|
0.8~1.0
|
長(zhǎng)春
|
21.7
|
0.3~0.5
|
0.4~0.6
|
0.4~0.7
|
0.5~1.0
|
0.6~1.0
|
0.8~1.0
|
0.8~1.0
|
哈爾濱
|
21.9
|
0.3~0.5
|
0.4~0.6
|
0.5~0.7
|
0.6~1.0
|
1.0
|
1.0
|
1.0
|
齊齊哈爾
|
21.9
|
0.3~0.5
|
0.4~0.6
|
0.5~0.7
|
0.6~1.0
|
1.0
|
1.0
|
1.0
|